Search results for " Dosimeter"

showing 10 items of 30 documents

Silicon dosimeters based on Floating Gate Sensor: design, implementation and characterization

2020

A rad-hard monolithic dosimeter has been implemented and characterized in a standard 180 nm CMOS technology. The radiation sensor (C-sensor) is based on a Floating Gate (FG) MOS discharge principle. The output current is processed by a current-to-voltage (I/V) interface and then converted by a 5-bit flash ADC. The dosimeter is re-usable (FG can be recharged) and can detect a dose up to 1krad (Si) with a resolution of 30rad (Si) typical over temperature 0 to 85°C range. The ADC allows easy further signal processing for calibration and averaging, etc. The power consumption of C-sensor plus I/V interface is < 2mW from a 5 V power supply. The overall layout area is less than 0.25mm2. The Rad…

010302 applied physicsSignal processingMaterials scienceDosimeterSettore ING-IND/20 - Misure E Strumentazione Nucleari010308 nuclear & particles physicsbusiness.industryAnalog-to-digital converterHardware_PERFORMANCEANDRELIABILITYFlash ADC01 natural sciencesPower (physics)law.inventionCMOSlawAnalog-to-Digital converter current-to-voltage interfaces Dosimeter edgeless transistors (ELT) Floating Gate MOS radiation hardening by design (RHBD) total ionizing dose (TID)Absorbed dose0103 physical sciencesHardware_INTEGRATEDCIRCUITSCalibrationOptoelectronicsbusiness2020 IEEE 20th Mediterranean Electrotechnical Conference ( MELECON)
researchProduct

SU-E-J-69: Evaluation of the Lens Dose On the Cone Beam IGRT Procedures

2014

Purpose: With the establishment of the IGRT as a standard technique, the extra dose that is given to the patients should be taken into account. Furthermore, it has been a recent decrease of the dose threshold in the lens, reduced to 0.5 Gy (ICRP ref 4825-3093-1464 on 21st April, 2011).The purpose of this work was to evaluate the extra dose that the lens is receive due to the Cone-Beam (CBCT) location systems in Head-and-Neck treatments. Methods: The On-Board Imaging (OBI) v 1.5 of the two Varian accelerators, one Clinac iX and one True Beam, were used to obtain the dose that this OBI version give to the lens in the Head-and-Neck location treatments. All CBCT scans were acquired with the Sta…

Cone beam computed tomographyDosimeterbusiness.industryIsocenterGeneral Medicinelaw.inventionLens (optics)lawMedicineLaser beam qualityThermoluminescent dosimeterbusinessNuclear medicineBolus (radiation therapy)Image-guided radiation therapyMedical Physics
researchProduct

Diffusion coefficient of PVA Fricke gel dosimeters

2015

Fricke gel dosimeters based on various matrix has been studied for a long time as 3D dosimetric system for radiotherapy. Selfoxidation and loss of spatial resolution due to diffusion have been the main issues that have impaired the affirmation of this technique so far. As part of an Italian nation-wide research program, we were interested in develop new gel formulations that are simple, reproducible and non toxic. We studied the one dimensional diffusion coefficient of Fe3+ ions inside Fricke gel dosimeters based on a matrix of PVA cross-linked with a di-aldehyde. With a spectrophotometer equipped with a moving tray we were able to collect absorbance measurements at different positions of t…

DIFFUSIONSSettore ING-IND/20 - Misure E Strumentazione NucleariPVASettore FIS/01 - Fisica SperimentaleGEL DOSIMETERSOPTICAL DENSITYSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Phenol compounds for Electron Spin Resonance dosimetry in gamma and neutron field

2016

The use of neutrons for cancer treatments has stimulated the research for beam characterization in order to optimize the therapy procedures in Neutron Capture Therapy (Altieri, 2008). Several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Spin Resonance (ESR) dosimetry to radiotherapy with different types of radiation beams. In particular, ESR spectrometry provides absorbed dose measurements through the detection of the stable free radicals produced by ionizing radiations. The ESR dosimetric method has many advantages such as simple and rapid dose evaluation, the readout procedure is non-destructive, linear response of many organic a…

ESR EPR Solid state dosimeters neutronsSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

PVA-GTA Fricke gel dosimeters exposed to clinical photons beams: Nuclear Magnetic Resonance Relaxometry and Imaging

2016

Fricke Gel (FXGs) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. The application of Fricke gels for ionizing radiation dosimetry is continuously increasing worldwide due to their many favorable properties. However, one of their shortcomings is that ferrous and ferric ions diffuse in the gel matrix. To maintain the spatial integrity of the dose distribution, Fricke gels must be undergoing measurement within a few hours of their irradiation, so that ferric ions remain close to their point of production. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained (Schreiner, 2015). The gel matrix also contributes to the oxidati…

Gel Dosimeters NMR MRI PVA GTA 3D DoseSettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Influence of the simultaneous calibration of multiple ring dosimeters on the individual absorbed dose

2021

Abstract Ring dosimeters for personal dosimetry are calibrated in accredited laboratories following ISO 4037-3 guidelines. The simultaneous irradiation of multiple dosimeters would save time, but has to be carefully studied, since the scattering conditions could change and influence the absorbed dose in nearby dosimeters. Monte Carlo simulations using PENELOPE-2014 were performed to explore the need to increase the uncertainty of H p 0 .07 in the simultaneous irradiation of three and five DXT-RAD 707H-2 (Thermo Scientific) ring dosimeters with beam qualities: N-30, N-80 and N-300. Results show that the absorbed dose in each dosimeter is compatible with each of the others and with the refere…

Materials scienceDosimeterRadiation Dosimetersbusiness.industryMonte Carlo methodPublic Health Environmental and Occupational HealthCoverage probabilityGeneral Medicine030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOptics030220 oncology & carcinogenesisAbsorbed doseCalibrationCalibrationDosimetryComputer SimulationIrradiationRadiometryCalibration ISO 4037 Monte Carlo Personal dosimetry Ring dosimetersbusinessMonte Carlo MethodWaste Management and DisposalBeam (structure)Journal of Radiological Protection
researchProduct

Study of the glow curves of TLD exposed to thermal neutrons.

2007

The glow curves of thermoluminescent dosimeters (TLD600, TLD700 and MCP), exposed to a mixed field of thermal neutrons and gamma photons are analysed. The fluence values of thermal neutrons used, comparable with those used in radiotherapy, allow one to define the reliability of the TLDs, in particular the most sensitive MCP, in this radiation field and to get information on the dose absorbed values. The glow curves obtained have been deconvoluted using general order kinetics and the observed differences for the different LET components have been analysed. In particular, the ratio of the n(0) parameter of two different peaks seems to allow to discriminate the different contributions of neutr…

Materials sciencePhotonHot TemperatureThermoluminescenceAstrophysics::High Energy Astrophysical PhenomenaPhysics::Medical PhysicsRadiation DosageThermoluminescenceFluenceSensitivity and SpecificityRadiation ProtectionDosimetryRadiology Nuclear Medicine and imagingNeutronComputer SimulationNeutron beamNeutronsRadiationDosimeterRadiological and Ultrasound Technologybusiness.industryPublic Health Environmental and Occupational HealthReproducibility of ResultsGeneral MedicineEquipment DesignModels TheoreticalSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron temperatureEquipment Failure AnalysisComputer-Aided DesignThermoluminescent DosimetryThermoluminescent dosimeterAtomic physicsNuclear medicinebusinessBeam (structure)Radiation protection dosimetry
researchProduct

Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures

2018

Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of …

Materials scienceeye lens doseTLDImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsProtective Clothingfashionbackscatter correction factorCalibrationmedicineDosimetryFluoroscopylead apronWaste Management and DisposalDosimetermedicine.diagnostic_testRadiation Dosimetersbusiness.industryEquivalent dosePublic Health Environmental and Occupational HealthEquipment DesignGeneral MedicinefluoroscopyLeadFluoroscopy030220 oncology & carcinogenesisfashion.garmentCalibrationLead apronThermoluminescent DosimetryThermoluminescent dosimeterbusinessJournal of Radiological Protection
researchProduct

Statistical methods for determining components non-liniarities, from thermoluminescent devices

2016

Thermoluminescent (TLD) dosimeters enjoy wide usage due to low cost and simplicity of use. They have however large errors at high doses in mixed-radiation fields, where non-linear effects occur. Algorithms based on the Akaike criterion [1] are presented for determining the maximal (physically meaningful) polynomial order with which the non-linearities are modeled. This depends on the number of points existing on a curve and on the points' errors.

Mathematical optimizationmedia_common.quotation_subjectPhysics::Medical PhysicsPolynomial order02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesThermoluminescence0103 physical sciencesAkaike criterionHigh dosesThermoluminescent dosimeterSimplicity010306 general physics0210 nano-technologyAlgorithmmedia_commonMathematics2016 IEEE 22nd International Symposium for Design and Technology in Electronic Packaging (SIITME)
researchProduct

Neutron dosimetry by means of electron spin resonance (ESR) tecnique

2012

Along with the Neutron Capture Therapy (NCT) development and with the use of thermal neutrons for radiotherapeutic purposes, many efforts have been devoted to the beam characterization in order to optimize the therapy procedures. Reliable dosimetric measurements should be able to determine the various components (neutronic and photonic) of the mixed beam usually employed for therapy. We have studied the effect of the additive such as gadolinium and 10B-boric acid on the neutron sensitivity of alanine ESR dosimeters exposed to a gamma and mixed (n, gamma) field mainly composed by thermal neutrons. We have chosen both this additive nuclei because of their very high capture cross section to th…

Neutron dosimetryalanine ESR dosimetersSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct